Liquid capacity

View Markdown

Liquid capacity lets other customers’ compatible On Demand work use your idle CPU or GPU capacity. Enable lending once, return through your usual Start or Connect action, and earn Nodus credits between uses. Availability requires published sharing terms and qualified capacity. Each machine serves one Org at a time.

This guide describes the Nodus credit agreement. If your displayed agreement instead says CashUSD, follow Cash earnings and payouts. A credit agreement does not authorize cash withdrawals.

In BYOC → Pools & machines, open your pool. Under Idle capacity, set Make idle capacity available on demand? to Yes. This accepts the displayed lending agreement for current and future hosts in that pool. Each host must qualify before lending. The published agreement gives you 50% of eligible settled compute charges in Nodus credits. It records a hardware rate card and reclaim notice; each loan freezes its whole-host rate. Prices are a static snapshot of the lowest matching Nodus website prices. GPU pricing follows the model and physical device count. CPU pricing uses the cheapest proportional published configuration for the host’s vCPUs and usable guest memory. Read the lending terms. Earnings appear after the borrower’s compute charge settles and cleanup finishes. Open Lending details and terms for the host table and agreement. The host table shows which machines are available, lending, reclaiming or awaiting cleanup, with net settled earnings for each host. The host table shows your earning rate per occupied host-hour; idle time earns no credits and demand is not guaranteed. Earnings are spendable Nodus credits; outstanding debt is paid first. Purchased credits and earlier liquid earnings fund owner compensation. Promotional credits do not. Refunded compute charges reduce the corresponding earnings, including after settlement.

Start, an authorized connection or a valid Job targeting your capacity requests its return without changing your Yes. Nodus stops new loans, recovers compatible borrowed work and cleans the original capacity before opening owner access. Looking at status or logs does not request its return. When your work ends, the capacity qualifies again and becomes available under the same permission. Disconnecting SSH does not make background work idle.

To manage a single enrolled machine, open it from BYOC → Pools & machines → Nodes or your pool’s Nodes tab. Its Idle capacity switch and Availability settings apply only to that machine. The page uses the machine’s own pool and project, even when a different project is selected in the console. A machine’s own No takes precedence over pool-wide Yes.

Hardware without a published lending rate stays unavailable for lending. The page shows this before you enable permission; choosing Yes does not add a price or guarantee earnings. Private use remains available. While lending is enabled, open Lending details and terms to compare the recorded agreement with the current published terms. Reading them does not reclaim work or change your agreement. To accept different terms, choose No to reclaim, review the new rate card, then choose Yes. The card must cover your hardware.

Choose No to stop lending and reclaim existing loans without releasing capacity. For reserved hosts, the reservation continues. Release reserved capacity is a separate action. Read its charge and availability consequences before confirming. Reuse waits for verified cleanup; an offline or failed machine cannot promise an immediate return.

In Billing → Overview, Liquid capacity shows the current UTC month’s reservation charges, earned credits, adjustments, credits actually applied to reservations and other Nodus charges, and net reservation charges. The coverage percentage uses posted credit applications; money held for future work has not been spent. The remaining earned balance carries forward without expiring. Running loans appear after settlement and cleanup. Credits are noncash. For externally billed BYOC, they offset eligible Nodus charges; your external cloud invoice continues under its own terms.

In Reserved Compute, open a physical server and choose Yes under Idle capacity. This agreement applies only to that server and its current active reservation. Use Connect to request the server’s return; SSH opens after borrowed work stops and cleanup passes. You do not need to choose No for ordinary use. Renewed or resumed reservation epochs require a new acceptance. Pool-wide permission never opts a reserved server in, and a machine’s own No takes precedence over Pool-wide Yes.

In BYOC → Cloud accounts, open your account and find Your connected machines. Each enrolled machine has an Idle capacity control. For an existing machine that is not connected yet, use Connect machine or Connect existing machine, choose a pool and run its one-time install command as root. A cloud account connection alone grants no execution or sharing permission. Hosts still need the documented isolation and GPU qualification before lending; you continue paying your cloud for the machine.

Qualified managed reserved environments have the same Idle capacity control in their existing details. Review and accept the displayed continuing base charge before enabling lending. Stop saves your home and ends your session while retaining the original capacity. The base charge continues during use, idle time, lending and normal handoffs; a session covered by this reservation adds no second compute charge. Start returns the original clean capacity and restores your saved home. Release ends charges at the confirmed release boundary. Environments without accepted retention keep their ordinary stop and deprovision behavior.

Open Availability settings to set recurring owner-use windows in your time zone, a one-time ready-by request, or a minimum number of compatible machines held ready for you. The defaults lend whenever idle, with no windows and no extra machines held back. Windows reserve availability and never stop active owner work; explicitly configured Workspace stop schedules still apply. Manual owner use takes priority. Capacity details show the current return stage and measured estimates when enough history exists, and identify a missed ready time.

Submit your Job normally. Nodus automatically compares compatible liquid hosts with other matching capacity on expected cost to completion. There is no borrower opt-in or liquid-capacity checkbox. Your interruption, network, storage, region and private-pool requirements still apply. Liquid jobs use purchased credits or previously earned liquid credits. Promotional credits remain usable on other eligible capacity. A liquid job stops gracefully when its eligible funding runs out, even if promotional credit remains.

Compatible CPU and GPU Jobs must support checkpoint recovery or explicitly declare safe retries. Work that forbids interruption uses other compatible supply. Qualified single-host TrainingJobs can use pinned, read-only model, dataset and parameter inputs with supported checkpoint recovery. Multi-node and unsupported interactive work use other supply. Recovery preserves your budget and accepted price ceiling. If replacement capacity is unavailable, the borrower waits while the owner gets their capacity back. Logs and outputs from earlier attempts remain available; saved files restore progress only when your program loads them, not process memory.

Host owners can inspect Job data; use explicit private-Pool placement for Jobs that must stay on your own infrastructure. Jobs with secrets, private registry credentials, arbitrary volumes or sidecars use other eligible capacity. Community-host Job egress must be Deny; scratch disk must fit the memory request. These hosts use file snapshot recovery. PyTorch DCP needs access to checkpoint storage and runs on compatible managed capacity with Open networking. Nodus preserves the network policy you requested when choosing capacity. The image root is read-only. Write results and recovery state in their declared Nodus directories.

apiVersion: nodus.dev/v1
kind: Job
metadata:
name: community-cpu
namespace: default
spec:
image: nodus/python:3.12
command: [python, -c, "print(sum(range(1000000)))"]
resources:
cpu: "1"
memory: 1Gi
disk: 1Gi
placement:
interruptible: Allow
recovery:
continuity: Restartable
network:
egress:
policy: Deny

Watch the Job and retrieve logs and outputs through the usual Job commands. Automatic matching considers this supply when eligible; it does not guarantee placement or a particular host. Rate ceilings, budgets and location constraints still apply. Enrolled community hosts have no verified region, so a Job requiring a specific region will use other matching capacity.

For GPU work, request a GPU model and count, as in examples/pools/liquid-gpu.yaml. NVIDIA hosts must pass CUDA execution and cleanup checks. A whole host is lent exclusively; only the requested GPUs are visible to the borrower. Hosts with unsupported drivers, MIG partitions or failed device cleanup stay unavailable. CPU jobs do not occupy GPU hosts.

Host readiness checks owner activity, CPU load and available memory before offering capacity and again before launch. Handoffs, restarts and hardware or runtime changes require fresh qualification. Draining a host triggers reclaim; removing it waits for cleanup. Failed qualification keeps capacity unavailable.

Published checkpoints and outputs are immutable revisions. Credentials from an earlier borrower attempt cannot overwrite an accepted revision or the next attempt’s upload area.